| The Association Group Info Report command now correctly identifies the type of each group and the command classes that will be sent. The default remains a relative percentage. Note that the RevH boards cannot do lux – they only have percentage. The red color channel would get lost on RevJ boards when the temperature was Program Size: data=164.3 xdata=8039 const=191 code=49341įor all RevJ and higher boards (serial numbers above 0x2000), the LUX scale has been added. v1.6: Add LUX scale for light level for RevJ units.The blue channel of the LED would get lost when the luminance is measured on RevJ boards (RevH boards do not have this problem). NWI exclusion mode ends as soon as the blue LED stops flashing with this revision. | If a controller goes into NWI exclusion mode, HSM200 could be excluded without pressing the button. | LearnMode was left enabled after the button was pressed in previous revisions. This shorter timeout makes it possible to use OnTime=0 mode more effectively. | The minimum timeout for sending a motion notification when OnTime is set to 0 has been reduced from 1 minute to 10 seconds. Note that Rev H only has luminance in percent. Rev H is 0x01. For Rev H boards, the luminance sensor always returned 0 in Rev 1.7. The Version Report command (V2) now replies with a Hardware Version of 0x02 for on RevJ hardware and later. V1.8: Add Hardware version to Version report command The odd minor revs are reserved for branches. | FCC testing mode has changed to support 5 different modes. They are rare but frequent enough it was decided to put additional checking in to reboot if there are more than 10 frame delivery failures in a row or if it has been more than 18 hours since the last communication. Reports of nodes requiring a power cycle to get them to talk again were coming in.
#Homeseer speaker client for mac upgrade
ZWave Library 6.81.00 – ONLY FOR UNITS WITH SCREW TAB!Īdded the Supervision Command Class to the non-secure NIF.
#Homeseer speaker client for mac update
| To get the settings for the changes, please update to the latest Beta of the Z-Wave plugin 3.0.1.234 or later. Note that a central scene command for single taps IS still sent. When disabled, the load will respond instantly to paddle presses. | Ability to disable the multi-tap feature on both WS and WD. This allows other WX200 devices to used as companion switches. Any device added to group 2 will be controlled. v5.12: Added a parameter to allow for lower dimming on the WD200.This ensures that both dimmers LEDS stay in sync. v5.13: When using group 2 association the controlling dimmer will send a BASIC SET to the associated dimmer after it reaches the desired dim level.
#Homeseer speaker client for mac install
If you install it on any other device, it may render that device inoperable. If it fails, do a connectivity check, then remove.Ĭareful: Be sure to install this dimmer firmware on the HS-WD200+ dimmer. After adding the switch back in, click on the old device then Z-Wave tab, then “Remove Bad Node” to remove the node from the Z-Wave interface. You will need to add the switch back into your network. This was an unfortunate consequence of adding the group 2 association feature. Note: When updating to this firmware the node ID of the switch will be lost. v5.14: Fixed multiple taps controlling the load (multiple taps should not control the load) | Modified parameter 5 to specify the lowest dim level the dimmer will provide (6.5% -> 20%) (Values are 1-14) | Z-Wave plugin version 3.0.1.249 required in order to set the lowest dim level parameter from the device Z-Wave settings.